800W

Server,Workstation,Storage System,Communication,Networking

305.00x79.00x40.00 (mm)
12.01x3.11x1.57 (inch) |
|

VOLTAGE: 90~264VAC FULL RANGE
FREQUENCY: 47~63HZ
INPUT CURRENT:6A(RMS)FOR 230VAC, 12A(RMS)FOR 115VAC
INRUSH CURRENT:18A MAX. FOR 115 VAC PER MODULE, 36A MAX. FOR 230 VAC PER MODULE
PFC CAN REACH THE TARGET OF 95% @110V, FULL LOAD,
OLLOWING THE STANDARD OF EN 610003-2, CLASS D
 |
| Output Voltage |
Output Current Min. |
Output Current Max. |
Output Current Peak |
Regulation Load |
Regulation Line |
Output Ripple & Noise Max.[P-P] |
| +12V |
2.0 |
65.00 |
|
±5% |
±1% |
120mV |
|
|
 |
| +5VSB |
0.1 |
0.8 |
|
±5% |
±1% |
50mV |
|
|
 |
 |

* TEMPERATURE RANGE:OPERATING 0℃~40℃,STORAGE -20℃~80℃
* HOLD UP TIME:WHEN POWER SHUTDOWN DC OUTPUT 12V MUST BE MAINTAIN 16mSEC IN REGULATON LIMIT AT NORMAL INPUT VOLTAGE.
* EFFICIENCY:TYPICAL 85% at 115V, FULL LOAD
* POWER GOOD SIGNAL:ON DELAY 100mS TO 500mS,OFF DELAY 1Ms
* OVER POWER PROTECTION:110~160% MAX
* OVER VOLTAGE PROTECTION: +12V→13.9V~16.4V
* LEAKAGE CURRENT: 3.5MA. MAX. AT NOMINAL VOLTAGE 250VAC
* SHORT CIRCUIT PROTECTION
* OVER CURRENT PROTECTION
* REMOTE ON/OFF CONTROL
* SAFETY:TO MEET UL&CUL, TUV, CCC, RFI/EMI STANDARDS |
|
|
|