| * Simple-to-use SAN switch with easy-to-install and easy-to-use features designed specifically for the needs of small to medium-size environments * Provides new levels of performance with 8 Gbps Fibre Channel (FC) technology * “Ports on Demand” scalability from 8 to 16 to 24 ports * Protect existing 4, 2 and 1 Gbps infrastructure investment while positioning for future technologies * Foundation for new infrastructure simplification and business continuity solutions for servers running Microsoft® Windows®, Unix®, Linux® and IBM AIX® and OS/400® operating systems |
The IBM® System Storage™ SAN24B-4 Express fabric switch is designed specifically to address the needs of small to medium-sized SAN environments. It can be used to create a wide range of high-performance SAN solutions, from simple, single-switch configurations to larger, multi-switch configurations which support fabric connectivity and advanced business continuity capabilities. Infrastructure simplification solutions for IBM System x™, BladeCenter® and IBM POWER Systems™ servers include storage consolidation and high-availability server clustering with IBM System Storage disk storage arrays. Business continuity solutions include data protection with IBM System Storage tape libraries and devices and IBM Tivoli® Storage Manager data protection software.

A single SAN24B-4 Express switch can serve as the cornerstone of a Storage Area Network for those who want to obtain the benefits of storage consolidation and are just beginning to implement Fibre Channel storage systems. Such an entry-level configuration can consist of one or two Fibre Channel links to a disk storage array or to an LTO™ tape drive. An entry-level eight-port storage consolidation solution can support up to seven servers with a single path to either disk or tape. The “Ports on Demand” feature is designed to enable a base switch to grow to sixteen and twenty-four ports to support more servers and more storage devices without taking the switch offline. A high-availability solution can be created with redundant switches. This capability is ideal for server clustering environments. Such a configuration can support from six to twenty-two servers, each with dual Fibre Channel adapters cross-connected to redundant SAN24B-4 Express switches which are cross-connected to a dual-controller storage system. While the focus of the SAN24B-4 Express is as the foundation of small to medium-sized SANs, it can be configured to participate as a full member in an extended fabric configuration with other members of the BM System Storage and TotalStorage® SAN b-type and m-type families. This capability helps provide investment protection as SAN requirements evolve and grow over time.
| Specifications | |
| Produce Number | 2498-B24 and 249824E |
| Base fabric switch | IBM System Storage SAN24B-4 Express switch with 24 ports, 8 ports activated (0 to 7) and Brocade Fabric OS (FOS) 6.1.0 or later, hardcopy Installation Guide, CD-ROM (with manuals), service and wrap tools, SFP extraction tool, 110 volt power cord for rack installation, rail kit, Advanced Zoning, Enhanced Group Management (EGM) (standard on 2498-B24, optional on 249824E), EZSwitchSetup wizard, Full Fabric (standard on 2498-B24, optional on 249824E), Web Tools |
| Fibre Channel interface | E_Port, F_Port, FL_Port and M_Port |
| Optical transceivers | Choice of 8 Gbps (supports 8, 4 and 2 Gbps link speeds) and 4 Gbps (supports 4, 2 and 1 Gbps link speeds) short wave and long wave Small Form-Factor Pluggable (SFP) |
| Fans and power supplies | Dual fans, one power supply |
| Hot-swappable components | SFP optical transceivers |
| Non-rack support | Non-rack installation is supported; country-specific power cords are required and must be ordered |
| Servers supported* | * IBM POWER Systems™, System i® and selected AS/400® servers, System p® and selected RS/6000® servers * System x, selected Netfinity® servers and other Intel® processor-based servers * Select Sun™ and HP servers |
| Operating systems supported* | * Microsoft Windows NT®, Windows 2000, Windows 2003 * Red Hat Linux, Red Hat Linux Advanced Server * SUSE Linux, SUSE Linux Enterprise Server (SLES) * IBM AIX, HACMP, i5/OS®, OS/400 * Other selected operating systems |
| Storage Products Supported* | * IBM System Storage DS8000™, DS6000™ and DS4000 storage servers * IBM TotalStorage Enterprise Storage Server® systems * IBM TotalStorage FAStT Family of storage servers * IBM System Storage n Series NAS Filers and Gateways * IBM TotalStorage 3580, 3588, 3590, and 3592 tape drives * IBM TotalStorage 3494, 3582, 3583 and 3584 tape libraries * IBM TotalStorage 3581 Tape Autoloader * IBM TotalStorage 3584 High Availability Frame Model HA1 * IBM TotalStorage SAN Volume Controller * Other selected storage systems |
| Fibre Channel switches supported | Current IBM System Storage and TotalStorage SAN b-type and m-type switches, routers and directors (must be running current firmware) |
| Fibre optic cable | Fibre optic cables are required and are available in various lengths in single-mode and multi-mode formats |
| Power cord | Jumper cable is included for rack installation; country-specific power cord must be ordered for desktop/standalone installation |
| Optional features | |
| 8-Port Activation, Adaptive Networking, Advanced Performance Monitor, Enterprise Package**, Extended Fabric, Fabric Watch, Full Fabric (standard on 2498-B24, optional on 249824E), Trunking Activation | |
| Physical characteristics | |
| Height | 4.29 cm/1.69 inches |
| Width | 42.88 cm/16.88 in |
| Depth | 30.6 cm/12.07 in |
| Weight | 4.35 kg/9.3 lb |
| Temperature | Operating: 0° to 40° C (32° to 104° degrees F) Non-operating: -25° to 70° C (-13° to 158° F) |
| Humidity | Operating: 10% to 85% non-condensing at 40° C (104° F) Non-operating: 10% to 90% non-condensing at 70° C (158° F) |
| Power | 85 – 264 V AC (Universal), 47 – 63 Hz |
| Feature | Benefits |
| Efficient 1U design | High-density 8, 16 and 24-port configurations |
| Auto-sensing 8, 4, 2 and 1 Gbps ports | Designed to |
| * Enable high performance and improved utilization * Enable rapid switch deployment with minimal set-up * Prove easy installation and manageability * Offer future readiness for 8 Gbps capable servers and storage devices |
|
| Hot swappable SFPs | * Provides fast and easy replacement of optical transceivers with no tools required * Support for both short wave and long wave optical transceivers |
| Inter-Switch Link (ISL) Trunking | * Support for up to 8-port ISLs provides total bandwidth of 128 Gbps * Helps eliminate packet rerouting and possible application failure due to link failure |
| Advanced Zoning | Hardware-enforced zoning helps protect against non-secure, unauthorized and unauthenticated network and management access and World Wide Name spoofing |
| N_Port ID Virtualization | * Allows each host image behind the same physical Host Bus Adapter (HBA) to connect to an F_Port using a unique N_Port ID to help maximize port usage in a virtualized server environment |
| EZSwitchSetup and Web Tools | * Quickly guides novice users through setup * Helps simplify administration and configuration |
| Hot firmware activation | Designed to: |
| * Significantly reduce firmware installation time * Enable fast firmware upgrades * Help elimination disruption to existing fabric * Help reduce administrative overhead |
|
| N+1 cooling | * Helps maximize fabric uptime when a fan fails |
| Upgradeable architecture for scalable SAN fabrics | * Optional features enable upgrades to support more complex fabrics * Modular upgrades enable a “pay as you grow” approach to adding features when needed |
| Backward compatibility with IBM SAN b-type and m-type fabrics | Helps provide investment protection for existing fabrics Allows inter-operation with other SAN products manufactured by Brocade Supports Native Interoperability with m-type products manufactured by McDATA (running current firmware) |